Dametric SKC9315710 Manual do utilizador - Página 3
Procurar online ou descarregar pdf Manual do utilizador para Cabos e conectores Dametric SKC9315710. Dametric SKC9315710 4 páginas. Rotating cable
RMS
3
MOUNTING INSTRUCTION
3.1 DISMOUNT THE OLD CABLE
Remove the cover for the TDC-sensor space in the rotor.
Remove the locking piece for the cable.
Remove the centering nut from the TDC-sensor.
Disconnect the bayonet connector of the cable from the TDC-sensor.
Remove the Safeset clutch.
Remove the TVD-TA1 transducer.
Remove the cable from the cable guide inside the rotating transformer.
Disconnect the cable from the rotating unit by holding the covers of the connectors and pull
them gently apart.
Remove the mounting clip for the cable on the centering plate.
Remove the cover of the connector from the welded sleeve of the metal tube.
Be careful of the connector and use no tools if not necessary.
Mount the brass cage (DD-DH15G) with the hauling wire to the welded sleeve of the tube.
Pull the cable from the transducer end thus replacing it with the hauling wire.
Remove the brass cage from the welded sleeve.
3.2 MOUNT THE NEW CABLE
Remove the cover of the contact from the welded sleeve of the metal tube of the new cable.
Be careful of the connector and use no tools.
Mount the brass cage (DD-DH15G) with the hauling wire to the welded sleeve of the tube.
Pull the hauling wire until the flange of the rigid metal tube of the cable rests on the designed
edge of the rotor.
Connect the bayonet connector to the TDC-sensor. Be careful to the surface (dia 17 mm)
outside the bayonet since the gasket inside the centering nut uses it.
Mount the centering nut to the transducer. Check that the surface on the TDC-sensor is flat so
that the surface works as a sealing together with the cupper washer on the centering nut.
At the other end, remove the brass cage and mount the attached O-ring and the cover of the
connector, use the attached tool to prevent rotation of the inner set.
Be careful of the connector parts.
Slide the cable through the hole of the centering plate and the coupling flange.
Fasten the cable to the centering plate with the mounting clip.
Connect the cable to the rotating unit by holding the covers of the contacts, position the
male/female by rotating them and then push them gently together.
Place the cable in the cable guide inside the rotating transformer, and mount the locking
screw.
Mount the TVD-TA1 transducer.
Mount the Safeset clutch.
K-DDRS1 EN.docx
Nov. 15, 2016 / DW
K-DDRS1
3(4)