DAMPP-CHASER Piano Life Saver System Manual de instruções de instalação - Página 7
Procurar online ou descarregar pdf Manual de instruções de instalação para Instrumento musical DAMPP-CHASER Piano Life Saver System. DAMPP-CHASER Piano Life Saver System 9 páginas. Backside vertical 8-part system which includes two humidifiers
Também para DAMPP-CHASER Piano Life Saver System: Instruções de instalação (4 páginas), Manual de instruções de instalação (8 páginas), Instruções de manutenção e cuidados (2 páginas)
STEP 5. LIGHT PANEL INSTALLATION
The two-light panel (Figure 18) features a green light marked
POWER, to indicate the System has electrical power, and a
yellow light marked WATER, which blinks when the Humidifier
needs water. There will be a single-light cube with a red light for
the Smart Bracket. The red light, marked PADS, will blink when
the pads need to be replaced. Connect the two-light panel and
single-light cube together (Figure 18) by inserting the tongue-
latch and two prongs (on the side of the single-light cube) into
the corresponding openings on the two-light panel. Insert the
metal prongs first while firmly pushing the panels together.
NOTE: the tongue-latch is slightly bent to create a snug fit
between the two panels.
To mount the light panel select (2) 19 mm screws and (3)
5 mm clamps with (2) 13 mm screws. Now, run the light panel
cord so that the panel is at an appropriate location under the
keybed. Usually this is at the extreme treble end beside the leg
of the piano. Use the two 19 mm screws to attach the light
panel under the keybed (Figure 19). Take the phone jack
adaptor from the light-panel and plug it into the Humidistat
outlet marked LIGHTS.
Be sure none of the cords/wires touch the Dehumidifier
rods, as exposure to heat can damage the cords/wires.
Conceal the cords/wires from the light panel using the 5 mm
clamps and a wire tie, if necessary.
Two-light
panel
A
FIGURE 20
Two types of clamps for Watering Tube
(A) standard clamp
(B) half clamp
SB
light
FIGURE 18
ongue-latch and prongs
T
insert in openings
B
STEP 6. WATERING TUBE INSTALLATION
The next step is to run the watering tube to the appropriate
location. You must be sure the tube will fit over the top of the
bottom panel. If the bottom panel pinches the tubing, check to
see if there is more space toward the middle of the panel. If it
does not fit, use your file to remove enough of the panel corner
to allow the tube to go through.
Two types of clamps are provided to anchor the watering tube:
(2)13 mm standard clamps and (2) 13 mm half clamps (Figure
20). Use 13 mm screws to mount the half clamps and 13 mm
screws for the standard clamps.
Figure 21 shows a typical watering tube installation. It's
important to curve the tube so it can be pulled out freely for
watering. To make this possible, the open side of the half
clamps should face the front of the piano. Serrated washers bite
into the wood and keep the half clamps in the proper position.
The end of the watering tube should extend beyond the first half
clamp by 3 cm to 5 cm. Position the standard clamps to prevent
sagging of the tube in locations that do not interfere with
replacement of the bottom panel.
After the Piano Life Saver System is completely installed,
plug the Humidistat into a non-switchable wall outlet where
it cannot be turned off and therefore will be fully energized at
all times.
Placement of Light Panel
half clamp
standard clamps
Placement of Watering Tube clamps
7
FIGURE 19
half clamp
FIGURE 21