DAN DRYER 244 Turbo Manual de manutenção e assistência técnica - Página 11
Procurar online ou descarregar pdf Manual de manutenção e assistência técnica para Secador DAN DRYER 244 Turbo. DAN DRYER 244 Turbo 12 páginas.
Reference
Version
244-ENG
09-01-2018
Heating element replacement
Warning !!!
During cleaning and service the hand dryer
must always be disconnected from the
power supply.
1.Disconnect power supply.
2.Disassemble cover by removing the two
cover screws at the bottom of the housing.
Use the special Allen key which was
originally supplied with the hand dryer.
3. Disconnect wires from timer unit.
4. Disassemble sensor bracket and
timer unit from fan housing.
DAN DRYER A/S • Tåsingevej 2 • DK-8940 Randers SV • Tel: +45 86 41 57 11 • Email: [email protected]
Document
244 DAN DRYER Turbo (with nozzle)
Maintenance and service manual
5. Loosen the two screws and dismount fan
housing from base plate.
6. Loosen the screws and disassemble air outlet
from fan housing.
7. Disassemble heating element from air outlet.
8. Assemble new heating element and
reassemble all other components.
9. Reassemble all components and test
run hand dryer.
Lang.
Page
ENG
11 of 12