Anyload DD-KC1 Manual de instruções - Página 6

Procurar online ou descarregar pdf Manual de instruções para Acessórios Anyload DD-KC1. Anyload DD-KC1 11 páginas. Digital weight indicator
Também para Anyload DD-KC1: Manual de operação (13 páginas)

Anyload DD-KC1 Manual de instruções
calibration point;otherwise, "0.0kg" will keep flickering to wait for the stable
weighing.
f) Repeat the step d) and step e) above,calibrate the half capacity range point
and the Full capacity range point orderly, save the calibrated parameters
automatically and return to the weighing mode.
4.5 Switching the Unit
Press the
4.6 Keeping Function "Hold"
Once the
4.6.1 The CPU will send the weight data into RS232 socket.
4.6.2 The weight will remain on the display for 120 seconds after the item has been
removed from the scale so the weight can easily be read.
a) Place the item on the scale platform.
b) Wait for the stable weights to be displayed.
c) Press the
d) Remove the item from the scale platform. The item's weight reading will
remain on the display for 120 seconds.
e) Quit to hold function: Once an item is weighed and the hold function is
enabled; when you want to quit to hold function, press the
to cancel the "►" hold indicator and return the scale to weight value.
4.7 Print output function
Press and hold the
for 2 seconds, then the buzzer will sound, and the weight data
will output to the computer or the serial printer.
4.8 Counting Sample
a. During counting mode, remove unrelated objects on the platform, then press
button to revert to zero;
b. Press
Page 6 of 11
button to switch the unit of measurement, kg --- lb--- pcs--- kg.
key is pressed:
key. The "►" hold indicators will turn-on.
button to switch the unit into "PCS", and the window will display
Anyload-manual-indicator-DD-KC1-en-101
key again