TROUBLESHOOTING

Symptom
Unit is plugged in but no lights are lighting on the
Alarm
Unit is plugged in, red alarm light(s) are ON but the
gauge(s) on the Autoswitch/Switchover is above the
alarm pressure.
Audible Alarm begins to sound as soon as power is
turned ON.
Output does not appear to be functioning.
SERVICE
Service by a factory authorized facility should be done if an Alarm becomes inoperative and troubleshooting has
not isolated the problem. Contact CONCOA Customer Service at 1-800-225-0473 for assistance.
If advised to return the unit for service you should:
1. Package the Alarm to prevent damage in shipping. If possible, use the original shipping materials.
2. Ship the unit back pre-paid.
3. Make sure the RMA number appears on the packaging and inside the package.
4. Include an explanation of the problem you encountered.
Cause
1. Check to see that there is power at the source.
2. Check that cable to Autoswitch/Switchover is
plugged in.
3. If the Alarm has been re-configured from the
factory settings, check that the DIP switches
were properly set. Refer to "Configuring the
Remote Alarm" section of the manual.
1. Check to see that the cable running between the
alarm and the Autoswitch/Switchover is properly
wired.
1. Check that the Autoswitch/Switchover
Connector is plugged in properly.
2. Check that the cable between the Autoswitch
and Alarm is not cut or pinched somewhere.
3. Check to see that all the wires in the cable are
properly soldered to the connectors.
1. Check the cable to the output device to be sure
it is properly connected.
2. Check the Output Connector to be sure it is
properly plugged into the Alarm.
3. Check the external output device to make sure it
is functioning properly.
-9-