11. Procedure to operate

To operate the Power Brake in AUTO mode, first place part in machine with flanges
down. A Notch Locator Blade is located in the brake area of the table to locate the
flange notches. Once the part is in the correct location and table is clear of any other
obstructions the operator can cycle the foot pedal. At this point the Press Bar assembly
will lower to clamp the part to table. Next the folder will swing up to brake the part. The
Folder will now swing down and the Press Bar will rise up off of the part. The part can
now be removed or repositioned for another brake. At any time during the sequence
the operator removes his foot from the pedal, the upper press bar and folding beam will
automatically return to its home position. Again it is imperative that the machine is set-
up and controlled with a single operator. Failure to do so can result in severe injury.
The brake is to be operated in compliance with its intended use. Any other purpose
does not constitute intended use. The manufacturer is not responsible for any damages
or injuries resulting from unintended use.
To operate the Power Brake in MANUAL mode, place the part in machine and operate
either the Press Bar or Folder assembly independently to set up the machine. Once the
part is located within the press the operator cycles the Press Down button.
confirming the part location the operator will then cycle the Manual Clamp button (while
still holding down the Press Down button). The Press Bar is operated manually up and
down with two buttons on the control box (Folder Up and Folder Down). Again it is
imperative that the machine is set-up and controlled with a single operator. Failure to
do so can result in severe injury. The brake is to be operated in compliance with its
intended use. Any other purpose does not constitute intended use. The manufacturer
is not responsible for any damages or injuries resulting from unintended use.
12. Ordering Replacement Machine PARTS
Replacement Machine PARTS may be ordered directly from Ductformer. All of the
following information is necessary to ensure the correct replacement PARTS are
provided:
Machine Model Number
Machine Serial Number
Replacement PART Number(s) – Description(s)
Quantity of PARTS (each)
Shipping and Billing Information
Contact Name, Company Name, Address and Phone Number
(PO Boxes are not acceptable addresses for shipment)
Preferred Shipping Method
OPERATING and PROCEDURES MANUAL
Page 10 of 12
TDFC POWER BRAKE
After