Anywave ATSC VHF 100W Manual de início rápido - Página 13
Procurar online ou descarregar pdf Manual de início rápido para Transmissor Anywave ATSC VHF 100W. Anywave ATSC VHF 100W 17 páginas.
If you are operating at a TPO less than 100W and wish to rerun corrections,
please proceed with the following steps, otherwise please skip ahead to step 12.
9. (Optional Step - Rerunning Corrections) If you are operating at reduced power
and wish to rerun corrections to achieve better performance, you may now
perform Linear and Non-Linear corrections. (Please refer to the Exciter User
Manual for detailed instructions on running corrections). Before running
corrections, it is important to verify proper feedback signal levels. There are two
feedback signal samples used to compute corrections. "RF IN A" (After BPF)
is used to calculate Linear correction coefficients while "RF IN B" (Before BPF)
is used to compute the Non-Linear correction coefficients.
10. (Optional Step) Navigate to the Exciter "DPD" submenu in the Advanced User
menu (simultaneously press Left and Right buttons, then simultaneously press
UP and Down buttons). Be sure the value of Feedback Sample Signal Input
(FSSI) for both A (after) and B (before) reads somewhere between 45% and 75%
- which roughly corresponds to a value of -15 to -5 dBm as measured on a power
meter (note: the FSSI indicator toggles between A and B and will "flash" when
the signal level is out of range, too high or too low). Add or remove the
appropriate attenuator padding to achieve feedback signal levels in the desired
range. Note the AFTER filter feedback sample is used to compute the SNR and
Shoulder Metrics displayed.
ACT-PAVIII1-QSG-DOC-V1.1, 06/26/2018
ATSC VHF 100W Quick Start Guide
Page 13 of 17