Airvent UV-C FiltAir Manual de instruções - Página 6

Procurar online ou descarregar pdf Manual de instruções para Equipamento de laboratório Airvent UV-C FiltAir. Airvent UV-C FiltAir 16 páginas.
Também para Airvent UV-C FiltAir: Manual de instalação rápida (2 páginas)

Airvent UV-C FiltAir Manual de instruções
Airvent UV-C FiltAir Instruction Manual

Unit Description

Operation

The unit is used for efficient sterilization of indoor air. The unit
works as follows (from bottom to top):
1
The air is drawn into the unit at the bottom with the help of
the EC fans.
2
The air then goes through the filter which removes the
majority of airborne contaminants from the air.
3
The UV reactor sterilizes even the smallest remaining parti-
cles with UV-C radiation.
4
The sterilized air is then returned to the room through the
top of the unit. Please note that the unit has been designed
for rooms with internal height of 3 m. In case of higher inter-
nal height, please contact our sales team.
Infection carriers in aerosols from exhalation, sneezing and
coughing are particularly dangerous because they do not settle
due to their small size and can cause infection by floating in the
air for many hours. The advantageous airflow created by the
UV-C FiltAir sweeps down the airborne particles without vor-
tices and continuously sterilizes the room air through the unit.
CFD simulation of air moved by a UV-C FiltAir placed next to a wall in a room
with a ceiling height of 3 m.

UV-C Sterilization

In the first phase of operation, the device performs mechanical
cleaning: it removes solid contaminants from the air, and in the
second phase, it kills the pathogens that have passed through
the filter with UV-C radiation. UV-C radiation falls in the short-
wave range of the natural light spectrum, which, when used
properly, can be used safely and effectively for sterilization, as
shortwave ultraviolet radiation at 253.7 nm destroys the hered-
itary material of pathogens, preventing them from further infec-
tion. The UV-C tubes of the UV-C FiltAir are located in an optically
enclosed space, so the device can be used continuously even in
the presence of people. UV-C FiltAir germicidal light sources do
not generate ozone, so their continuous use is safe.
Attention!
The UV-C FiltAir is not to be used for sanitizing
surfaces in the room, it does not replace basic hygienic rules -
especially those described by the law -, rather complements them.
6