Duke RUF-48 M Manual de instalação e operação - Página 7

Procurar online ou descarregar pdf Manual de instalação e operação para Frigorífico Duke RUF-48 M. Duke RUF-48 M 8 páginas. 48” refrigerated counter digital with 1/3 size food pan insert
Também para Duke RUF-48 M: Manual de instalação e operação (12 páginas)

MANY FOOD PRODUCTS HAVE AN ACIDIC CONTENT WHICH CAN DETERIORATE THE FINISH.
BE SURE TO CLEAN ALL FOOD PRODUCTS FROM ANY STAINLESS STEEL SURFACE.
COMMON ITEMS INCLUDE, TOMATOES, PEPPERS AND OTHER VEGETABLES.
THE POWER MUST BE TURNED OFF AND DISCONNECTED AT ALL TIMES WHEN PERFORMING
MAINTENANCE – Cleaning the Condenser Coil
The condenser coil is located behind the unit (See Figure 5). This unit has a replaceable filter, discard old filters. The
condenser coil requires regular cleaning and is recommended every 60 days. However, in some instances you may
find that there is a large amount of debris, dust or grease that has accumulated prior to the 60 day time frame. In
these cases the condenser coil should be cleaned every 30 days.
If the build up on the coil consists of only light dust and debris the
condenser coil can be cleaned with a simple brush, heavier dust
build up may require a vacuum or even compressed air to blow
through the condensor coil.
If heavy grease is present degreasing agents are available for
refrigeration use and specifically for the condenser coils. The
condenser coil may require a spray with the degreasing agent and
then blown through with compressed air.
Failure to maintain a clean condenser coil can initially cause high
temperatures and exces¬sive run times. Continuous operation
with dirty or clogged condenser coils can result in compressor fail-
ures. Neglecting the condenser coil cleaning procedures will void
any warran¬ties associated with the compressor or cost to replace
the compressor.
NEVER USE A HIGH-PRESSURE WATER WASH FOR THIS CLEANING PROCEDURE AS WATER CAN
DAMAGE ELECTRICAL COMPONENTS LOCATED NEAR OR AT THE CONDENSER COIL.
Installation and Operation of: Refrigerated Counter RUF48 Digital
MAINTENANCE
WARNING
NEVER USE AN ACID BASED CLEANING SOLUTION!
WARNING
MAINTENANCE OR REPAIR FUNCTIONS.
CAUTION:
Filter (Condensing Coil is
Located behind unit.)
Figure. 5
7