(2) Standard (non-explosion-proof)

① Cabling
If the ambient temperature is 60[deg]C or less, use 600V vinyl or better stranded cable.
If the temperature is above 60[deg]C, select cable with an appropriate tolerance for the
conditions.
② Connecting the cables
TE100 (with terminal box)
To connect the cables, remove the terminal box cover and use the insulated crimping
terminals on the terminal block.
Connect by crimping the + input terminal to the + terminal (red) and the - input
terminal to the - terminal (blue). (See Figure 3-1)
TE200 (no terminal box)
Remove the main cover and connect to the terminal block on the circuit board as
described above.
The terminal polarities are indicated on the protective plate.
(See Figure 3-2)
Figure 3-2