Internal light
In order to reduce energy consumption, the LED light within this wine cabinet will
switch off when closed the door. If you would prefer the LED light to remain on continuously, this is
possible. Please press and hold the "LIGHT" bottom for 5 seconds, the display will show "LP".
After 4 seconds the display will revert back to normal and the light will remain on until manually
switched off.
If you would like to revert back and conserve energy (recommended), press and hold the "LIGHT"
button for 5 seconds, the display will show "LF". After 4 seconds the display will revert back to
normal, and the light will automatically switch off after 10 minutes
Note
If the unit is unplugged, power lost, or turned off, you must wait 3 to 5 minutes before restarting
the unit. If you attempt to restart before this time delay, the Wine cooler will not start.
When you use the Wine cooler for the first time or restart the Wine cooler after having been shut
off for a long time, there could be a few degrees variance between the temperature you select and
the one indicated on the LED readout. This is normal and it is due to the length of the activation
time. Once the Wine cooler is running for a few hours everything will be back to normal.
Temperature Recollection Function
In the event of a power interruption, wine cooler can remember the previous temperature settings,
and when the power is recovery, the cooler temperature will go back the same setting
temperature as power off.
Overtime Open the Door Alarm
When you forget close the door or the door is not closed completely, the buzzer alarm after 5
minutes. Please close the door completely and avoid the cold energy was lost.
Temperature Alarm
If inner temperature is higher than 23°C, The "HI" is shown in display panel, and the buzzer
alarm after one hour continuously. It inform that the inner temperature is too high, please check
the reason.
If inner temperature is lower than 0°C, The "LO" is shown in display panel, and the buzzer alarm
and the malfunction indicator light light at the same time.
Storage diagram
FOR DAB-42.117DB/DAB-42.117DSS
Total: 42 bottles (Max)
F
O
c
O
FOR DAB-48.125B/DAB-48.125SS
Total: 48 bottles (Max)
6
automatically