Installation Instructions
5.
Install the left and right brake terminals onto the brake terminal bracket using 4 M5 nuts. Torque to 2.3 Nm (20 in-lb).
6.
Secure the brake terminal assembly to the mains bus bar support with 2 M8 nuts. Torque to 9.6 Nm (85 in-lb). Refer to
Illustration 1.6.
7.
Assemble the mains bus bar subassembly using 9 stand-offs and 9 M5 nuts. Torque to 2.3 Nm (20 in-lb).
Refer to Illustration 1.8.
1
Mains bus bar support bracket
2
Stand-offs (front and back side of bus bar), indicated by an S in
the drawing
3
Slotted opening for M10 screw
Illustration 1.8 Assembling the Mains Bus Bar Subassembly
6
Bus Bar Kit for 6-pulse, 2-drive System
VLT® Series FC 102, FC 202, and FC 302
4
M5 nut
5
Brake terminal assembly (terminals and bracket)
6
Solid mains bus bars
Danfoss A/S © 02/2016 All rights reserved.