Danfoss EFET 160 Manual de instruções de instalação - Página 8
Procurar online ou descarregar pdf Manual de instruções de instalação para Termostato Danfoss EFET 160. Danfoss EFET 160 12 páginas.
Technical data
Temperature range
Operating voltage
Switching capacity
Switch
Hysteresis
Ambient temperature
Protection class
Sensor type
Sensor
LED indicator:
No light
Red
Green
8
-10°C - +50°C
180 - 250 V ~ 50 Hz
Cos φ = 0 .3 max . 4 A
10 A
± 0 .2°C
-30°C to +55°C
IP 44
NTC
-10°C
66 kOhm
0°C
42 kOhm
+25°C
15 kOhm
+50°C
6 kOhm
System is OFF .
System is OFF .
Heating is ON, but the set temperature has not
been reached .
Set temperature is reached and the heating is
turned off .
VIFZK102
02/2007