D.3.
OPTIONAL - programable fan/occupancy operation : If the programable fan/
occupancy option has been enabled by the installer, the operation of the fan can be set for
each event. Additionally each event can be programed as building occupied or unoccu-
pied. This feature is often tied in to the operation of fresh air dampers. Optimum Start
Control, if set by the building owner or installer, will also be applied to each occupied event
- please refer to installer. The available options are:
a)
Building occupied: Fan On, runs continuously (FAN ON symbol displayed, HOUSE
symbol displayed and static)
b)
Building unoccupied: Fan Auto, turns on and off with heat or cool demand (FAN AUTO
symbol displayed, HOUSE symbol displayed but flashing)
c)
Building unoccupied: Fan On, runs continuously (FAN ON symbol displayed, HOUSE
symbol displayed but flashing)
d)
Building occupied: Fan Auto, turns on and off with heat or cool demand (FAN AUTO
symbol displayed, HOUSE symbol displayed and static)
To select Fan Mode and Occupancy options, press
Press NEXT button to move onto event 2 programing and repeat steps D1 and D3 above
D.4. Press NEXT button to move onto events 3, 4, 5 and 6, repeating steps D1 – D3 until all
events are programed
!
Reminder - If thermostat has been set by the building owner or installer for 2 or 4
events per day, only 2 or 4 events can be programed, otherwise 6 events can be
programed
D.5. Press DAY button to advance to the next day. Repeat steps D1-D4 for each available day
(see 6 below)
D.6. OPTIONAL: Copy program from previous day into current day :
a)
Press COPY button to copy program forward from previous day
b)
Repeat as necessary for other days
!
Reminder - Copying Restrictions: Programs can only be copied forward from the
previous day. For example from day 1 to day 2, not from day 1 to day 3
!
Reminder - Thermostat may have restricted temperature settings : In some
installations the building owner or installer may have restricted the temperature
range of the heating and/or cooling. Please refer to the installer
Setting Template
!
Advice – Program setting template: A setting template is provided at the rear of this
document to record program settings
-
D.7.
REMINDER
THERMOSTAT SET IN
building owner or installer in 5-day / 2-day mode, display will be as opposite.
Programming: one set of programs for Days 1-5, another for Days 6-7
Copying: limited to copying from days 1-5 to days 6-7 or vice-versa
-
D.8.
REMINDER
THERMOSTAT SET IN
the building owner or installer in 24 hour mode, display will be as opposite.
Copying: not available
Programming: one program repeated each day
D.9. To return the thermostat to Run mode press PROG button
button to toggle to the required setting.
5/2-
: If the thermostat has been set by the
DAY MODE
24
: If the thermostat has been set by
HOUR MODE
LCD DISPLAYS
77
68
6 : 30
M
O
N
MO
77
68
6 : 30
M
UTO
MO
77
68
6 : 30
AM
N
M
81
59
6
PM
UTO
MO
81
59
6
PM
UTO
MO
Programming Event 6
time and temperature
77
68
6 : 30
M
O
N
MO
77
68
6 : 30
M
O
N
MO
Copying program
7 day mode
77
68
6 : 30
M
MO TU WE TH FR
Copying program
5/2 day mode
77
68
6 : 30
M
Copying not available
in 24 hour mode
BUTTONS
NEXT
NEXT
DAY
COPY
COPY
PROG
3