The TP4000 is both a programmer and a room thermostat. It allows you to programme
up to 6 times and temperatures at which your heating will come on and go off each
day.
Before programming the thermostat press and release the RESET button to restart
the unit. (Fig. 1)
Setting the Clock and Day
The time is set in the factory and therefore it will not normally be necessary to do this
on site.
Accepting the Factory Pre-settings
The TP4000 has pre-set times already programmed in, which often suit most people
(see table below).
Event
To adjust the factory pre-settings & set your own time and temperature
programmes
a) Press PROG (Fig. 2) Until 1st pre-set time and temperature appears in display (Fig.
3).
b) Use + or – buttons (Fig. 4) to adjust the TIME (press and hold to change in 10 min
increments).
c) Use Λ or V buttons (Fig. 5) to adjust the TEMPERATURE.
d) Press PROG (Fig. 2) to move to next preset time & temp (Event 2) (Fig. 6).
e) Repeat steps b, c & d for programming Events 3, 4, 5 & 6.
Returning to RUN mode
Press PROG (Fig. 2) – the colon in the LCD display will start to flash (Fig. 7).
Temporary User Overrides
The TP4000 has several useful overrides which can be selected without affecting the
thermostat programming.
•
Selection of time or actual room temperature in main LCD display – press +
and – together to change between settings (Fig. 8).
Temporary override of programmed temperature – press Λ or V until required
•
temperature is displayed (override will automatically cancel at beginning of next
programmed event) (Fig. 9).
Frost Protection – a constant low temperature can be selected whilst away from
•
home - press Λ and V together (Fig.10). Then use Λ or V to select the required
temperature. To return to automatic programming press Λ and V together
again.
TP4000
User Instructions
Time
Temp. °C
1
06:30
20
2
08:30
15
3
11:30
20
4
13:30
15
5
16:30
21
6
22:30
15
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
Fig.6
Fig.7
Fig.8
Selection of time
or actual room
temperature in main
LCD display
Temporary
Fig.9
override of
programmed
temperature
Frost
Fig.10
Protection
RESET
press
together