User Guide
9
Set Control Parameters
• Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set
the parameter range via < or >. Complete all adjustments.
• To exit press
, which is available for this purpose (automatic exit after 20 seconds with no operation).
The digits indicate the set value as follows:
No.
Parameter settings
P01
Working mode
P02
Heat control mode
P03
Heat control start-up mode
P04
Temperature limit high
P05
Temperature limit low
P06
Frost protect temperature
P07
Away mode temperature
P08
Timer display
P09
Service due setup
P10
RF Pairing (TP5001RF only)
P11
Auto daylight saving
10
Error Messages
E1
Sensor failure
EE
EEPROM failure
Lo
Measured temperature below 0 °C
Hi
Measured temperature above 50 °C
E3
RF Pairing failed
E4
RF Signal lost
Danfoss Heating
TP5001 Programmable Room Thermostats
01: Manual
02: Schedule timer 5/2 day
03: Schedule timer 24hr
01: On/off load compensation
02: On/off standard
01: Normal start control
02: Delayed start control
03: Optimised start control
Between low (P05) and 35° C
Between 5° C and high (P04)
Between 5° C and 15° C
Between low (P05) and high (P04)
01: 24hr
02: 12hr
Installer setting only
00: RF pairing mode off
01: RF pairing mode on
01: On
02: Off
VUSUF102 | BC306936081288EN-000102
Settings range
Default
02
01
01
35° C
5° C
5° C
18° C
24hr
00
01
09/2020