Dungs MPA 4122 V2.0 Manual do utilizador - Página 7

Procurar online ou descarregar pdf Manual do utilizador para Queimador Dungs MPA 4122 V2.0. Dungs MPA 4122 V2.0 16 páginas. Automatic burner control system
Também para Dungs MPA 4122 V2.0: Manual do utilizador (16 páginas)

6. Technical data for MPA 41xx
Protection class MPA 4112, MPA 4114
External display
Protection class MPA 4122
Ambient temperature
Storage and transport
Humidity
Operating altitude
Service life of switching outputs
Installation position
Dimensions MPA 411x in mm
Weight MPA 411x
Dimensions MPA 412x in mm
Weight MPA 412x
7. Electrical data for MPA 41xx
Rated voltage
Frequency
Fuse
Isolation
Electrical connection
Power consumption (own consumption)
Short-circuit current ION against N
7 ... 16
IP 54
IP 54 front / IP 20 rear
IP 65
-40 °C...+70 °C
-40 °C...+80 °C
DIN 60730-1, no dewing admissible
Suitable for use up to 2 000 metres above
mean sea level
At least 250 000 switching operations
Any
MPA 4112 / 4114 (L x H x D): approx.
152.5 x 165 x 77 mm
0.82 kg
MPA 4122 (L x H x D): approx. 160 x 240 x
100 mm
2.2 kg
230 VAC -15% ... +10% or 115 VAC -15%
... +10%
50 Hz ... 60 Hz
6.3 A delayed or 10 A fast-acting,
integrated, replaceable
No galvanic isolation between grid and
24 VDC or 5 VDC
In-phase connection and protective earth
connection according to connection
diagram
The touch protection for the UV sensor
must be ensured through installation in
the operating equipment
Maximum 10 W
115 / 230 VAC
280 µA

8. Inputs / outputs

Outputs
Designation
Safety-
Output type
relevant
V1 / V2
Relay contact
Gas valves
Ignition
Electr. relay
Fan
Relay contact
Operation / fault
Relay contact
Supply
Flame detector
*1 With a pre-ignition time > 100 s or a duty cycle (DC) > 80 % of the ignition output, the maximum permissible
output current is reduced to 1.5 A.
The total currents of all safety-related consumers must not exceed 5 A (note the safety value)
The total currents of all consumers must not exceed 6.3 A (10 A).
Inputs
Designation
Input type
Safety chain
Potential-free contact
Flame detector 1 (ionisation)
Ionisation
X 16 to X 20
Switching contact
e.g. remote unlocking, air pressure
monitor, heat request, flame detector 2
AM 41 display connetion
-
Use flame detector 2 for line lengths > 10 m.
For special applications, ionisation line lengths of up to 50 m are possible on request.
Different functions can be parameterised for inputs X 16 to X 20, see chapter tbd.
Safety devices in the safety chain must have potential-free normally open or normally closed contacts suitable
for mains voltage and at least 10 A current load.
The connection lines must be suitable for an ambient temperature of at least 75 °C.
Line
Electrical data
length
100 m
115 / 230 VAC / 2 A cos φ = 1 / minimum load
0.5 W
100 m
115 / 230 VAC / 2 A cos φ = 1*
100 m
115 / 230 VAC / 1 A cos φ = 0.4 corresponds
to 115 / 230VAC / 2.5 A cos φ = 1
100 m
115 / 230 VAC / 1 A cos φ = 1
100 m
230 VAC / 10 mA (also version MPA 115 VAC)
Line length
Electrical data
100 m
115 / 230 VAC / max. 5 A
10 m
Threshold: approx. 1.2 μA
100 m
115 / 230 VAC
10 m
internal