Dunham & Morrow DML2000 Manual do utilizador - Página 6

Procurar online ou descarregar pdf Manual do utilizador para Instrumentos de medição Dunham & Morrow DML2000. Dunham & Morrow DML2000 13 páginas. Magnetic locator

Operation

To begin operation, you must first Power On the instrument. Then, adjust the Volume Control
to a comfortable setting and set the Sensitivity Control to position 2 or 3.
Figure 2: Instrument Controls

Sensitivity Setting

Most search operations work well with the Sensitivity Control set to Level 2. For small and
relatively weak magnetic targets, a higher sensitivity setting may be desirable. Conversely,
when the operator is searching for large, relatively strong magnetic targets, a lower sensitivity
setting may be desirable.

Audio Output

When no magnetic objects are present, the instrument's audio output idles at approximately 20
Hertz. As the magnetic locator is swept back and forth in a desired search area, the speaker
output tone increases in frequency when/if the DML2000-XR approaches a magnetic object.