1. Make yourself magnetically clean. Typical items known to be magnetic include, but are not
limited to watches, key rings, pocket knives, belt buckles, and shoes with steel toe
protectors.
2. HOLD the instrument by the pistol grip located below the Electronics Box and on the top of
the instrument's Sensor Tube.
3. Turn the Volume Switch clockwise to activate the instrument and set the volume to a
comfortable level.
4. Set the Sensitivity Switch to position 3.
5. Sweep the unit back and forth in front of you as you walk and search the area. With no
magnetic (ferrous) targets present, the unit will idle at approximately 20 hertz. As you
approach a ferrous target, the frequency will increase and peak directly over the target.
6. For strong or shallow targets, raise the unit approximately 12 inches above the ground or
select a lower sensitivity setting. Conversely, for weak or deep targets you may wish to
increase the instrument's level of sensitivity.
Always remember that the DML2000-XRM and DML2000-XR are precision instruments
The DML2000-XRM is identical to the DML2000-XR with the exception that it also includes a
visual display (a full 3 ½ digital LCD panel meter) in addition to the audio output.
NEVER use the DML2000-XR as a substitute for a shovel
Quick Start Instructions
and should be treated accordingly.