Instruction
1.
Disassembling
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
1.
Tools required for dismantling.
3.
Dismantle the front cover using a vice.
5.
Remove the two small O-rings from the
flange. Remove the seal from the front
cover using a screwdriver.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
2.
Remove the parallel key and unscrew the
front cover.
4.
Remove the shaft seal using two screw-
drivers.
6.
Unscrew the four screws for the housing.
3