Danfoss PAHT G Series Manual de serviço - Página 9

Procurar online ou descarregar pdf Manual de serviço para Bomba de água Danfoss PAHT G Series. Danfoss PAHT G Series 20 páginas. Paht and paht g 256-308 disassembling and assembling
Também para Danfoss PAHT G Series: Instrução (20 páginas), Instruções de desmontagem e montagem (20 páginas)

Danfoss PAHT G Series Manual de serviço
Instruction
3.

Assembling

Disassembling and assembling PAH 2-6.3, PAHT 2-6.3, PAHT C 2-6.3 and PAHT G 2-6.3
2. Remove swash plate and guide pin.
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
1. Lubrication:
• To prevent seizing-up, lubricate all
threads with PTFE lubrication type.
• O-rings inside pump may be lubricated
only with clean filtered water.
• O-rings for port flange, mounting flange
and flushing valve must be lubricated.
• It is important to lubricate ALL parts to
be assembled with clean filtered water
(Especially all PEEK parts).
180R9094 / 521B0985 / DKCFN.PI.011.N5.02 / 09.2015
Guide pin
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.
2. Parts and tools required for assembly.
Check that all parts are OK. Replace all
seals.
9