T-480-HP Set-Up & Operating Instructions
1. Turn vent/ fill cap to "vent" position to vent
pump reservoir. Release the pusher clip
and slide pusher back. NOTE: Periodically
lubricate the die ring with Weatherhead
T-400-G lubricant. When crimping with
Coll-O-Crimp® I tooling, insert the T-420-25
adapter die ring into the base plate. Insert
the proper sized collet.
4. Holding uncrimped hose assembly in place,
refer to the PowerSource crimp spec tool at
danfoss.com/crimp for correct spacer ring.
Note: when crimping spiral-reinforced hose
(H430, H439, H470), a T-480-68 spacer ring
must be used to prevent damage to the
pusher. Position spacer ring on top of collet
with proper side of spacer ring facing up as
shown in figure B, page 12. and slide pusher
forward, making sure pusher clip has locked.
8 | PORTABLE COLL-O-CRIMP® Model T-480 Set up and operating instructions | 2022.10.
2. Select the proper Weatherhead hose
and end fitting. Insert the hose into the
end fitting, making sure that the hose is
bottomed in end fitting. For insertion depth
information, reference figure A, page 12.
5. Close release valve.
3. Loosen knob and tilt press as necessary.
Insert hose assembly from below the base
plate and between the collet halves. Align
dimples or knurl band on end fitting with
top of collet, making sure that collet halves
are evenly matched. When crimping H757
hose, position end fitting as shown in figure
D, page 12.
6. Operate pump handle until spacer ring
contacts the base plate indicating that the
crimp is complete. Open the release valve
to retract pusher. Release the pusher clip
and slide the pusher back to access tooling.
Remove the spacer ring and the crimped
hose assembly from below the base plate
and between the collet halves.
!
NOTE: Visually inspect the crimped end.
Check the nominal crimp diameter and verify
that the crimp is within 1/16" from the locating
dimples on the collar, see figure C, page 12.
BC425482205281en-000101