AETOOL BESA 11 Manual de início rápido - Página 7
Procurar online ou descarregar pdf Manual de início rápido para Instrumentos de medição AETOOL BESA 11. AETOOL BESA 11 8 páginas. Battery electrical system analyser
You need to switch ON all loads (Head
Lights, Radio, Air-condition, Heater, etc)
and press enter key will display as
follow:
Rev engine up to
2,000 rpm and
hold for 10 sec
Then press Enter
After that press
ENTER
show as below:
2000 RPM
13.89 V
Max 13.96 < 13.5 V
Min 13.76 > 12.5 V
Enter to proceed
4.9 Press
ENTER
key will show the
results of the test:
LOAD TEST
ChrgVolts: 13. 96V
Result: Good
4.10
If either minimum or maximum
charging volts are not within the
voltage range limits then it will
display one of the screen as below
(Fig. 3 & Fig. 4) and it will prompt you
to check the alternator system for the
fault.
key again and it
LOAD TEST
Min Charge: 12. 0V
Result: LOW
Check Alt System
Fig. 3
LOAD TEST
Max Charge: 13. 06V
Result: LOW
Check Alt System
Fig. 4
4.11
To exit the program, pressing the
key at any moment will exit and return back
to the main menu screen.
5. HELP KEY
Selecting this key will help you familiarize
with the analyser by explaining the various
functions and the results. To access to this
function, just press the
wakeup display:
How to operate▼
RESULTS
VOLTAGE
CCA
Use the Up or Down key to scroll to the next
item. To exit this function, just press the
key will return back to the main menu display.
HELP
key during the
EXIT
EXIT