Danfoss 4MFC-1015L Manual de instalação - Página 4
Procurar online ou descarregar pdf Manual de instalação para Equipamento industrial Danfoss 4MFC-1015L. Danfoss 4MFC-1015L 10 páginas. Multiplate coupling
4.0
DURABILITY AND LIFETIME
The durability and lifetime of the quick coupling system depend on the following:
Environmental conditions
•
Conditions of use
•
Timely preventive maintenance
•
Construction features of the on-site situation
•
5.0
MAINTENANCE
Components must be maintained after every 12 months storage period for the purpose of monitoring and repairs.
Replacement with original parts will ensure correct functionality.
Clean your quick coupling system once a week or every 50 coupling-decouplingcycles. To do this, use the usual cleaning
agents such as dry ice. After doing so, lubrication must be carried out.
Apply solid lubricant (grease) after every 6 months or 1000 coupling-decouplingcycles in critical areas listed below:
1. Racks on movable plate
2. Pinion in fixed plate
Figure 1.