3) CONTROLS POWER
P1
It set the power of the motor 1.
P4
It set the power of the motor 2.
4) DIP-SWITCH S1 FUNCTIONS
ON Automatic closing at the end of the work time-break after an opening controlled by the input of START.
DIP 1
OFF Automatic closing after the work time-break excluded.
Automatic closing at the end of the pedestrian time-break after an opening controlled by the input of
ON
DIP 2
PEDESTRIAN
OFF Automatic closing after the pedestrian time-break excluded.
ON Active command inputs as START and PEDESTRIAN.
DIP 3
OFF Active command inputs as OPEN and CLOSE separate
ON Input radioreceiver RX1 it works as terminal block START.
DIP 4
OFF Input radioreceiver RX1 it works as step-by-step.
ON Same time of work for both the motors on M1.
DIP 5
OFF Time of work separate and independent for both the motors.
ON The motor /s still works for 3 second after the activation of the limitswitch CLOSES
DIP 6
OFF The motor/s only works till the activation of the limitswitch CLOSES
ON Automatic closing at the end of the work time-break after an opening controlled by the input radioreceiver RX1.
DIP 7
OFF Automatic closing after the work time-break excluded.
ON SAFETY EDGE 2 during the opening, it stops the movement and it closes totally.
DIP 8
OFF SAFETY EDGE 2 during the opening, it stops the movement and it closes only for 2 seconds.
ON High threshold of starting encoder
DIP 9
OFF Low threshold of starting encoder
ON Short closing impulse on.
DIP 10
OFF Short closing impulse off.
4.1) DIP-SWITCH S2 FUNCTIONS
ON
Dead man working
DIP 1
OFF IMPULSIVE working.
Semiautomatic program. In opening it doesn't accept START impulses. It is possible to use it for the function
ON
DIP 2
clock.
OFF Program step-by-step: OPEN-STOP-CLOSE-OPEN
Maximum power to the motors in closing in the last 2" on.
ON
DIP 3
OFF Maximum power to the motors in closing in the last 2" off.
ON
Power starting motors on.
DIP 4
OFF Power starting motors of.
ON
In opening and time-break an impulse of Photocell 1 close again after 2."
Standard work on photocell 1
when the gate is closed and foto 1 obscurated ,the gate not open.
DIP 5
during the closing and foto 1 obscurated ,the gate stop and reopen when the foto1 is
OFF
liberated (in this operation is activated also the electrolock).
during the opening and foto1 obscurated ,the gate stop and reopen when the foto1 is
liberated (in this operation is activated also the electrolock).
ON
When the gate is closed, the START opens if PHOTOCELL 2 are obstructed.
DIP 6
OFF When the gate is closed, the START doesn't open if PHOTOCELL 2 are obstructed.
ON
Pre-alarm signal clinking 1 sec.
DIP 7
OFF Pre-alarm signal clinking 4 sec.
Output signal clinking intermittent.
ON
DIP 8
(during the closing: slow clinking, During time-break : fixed light. During the opening fast clinking)
OFF Output signal clinking fixed.
ON
Working with 2 motors (type double leaf).
DIP 9
OFF Working with 1 motor on M1 (type sliding gate or 1 leaf).
ON
Admittance to the planning menu.
DIP 10
OFF Disposition of the control panel in work condition.
Page 4 of 14
It set the sensibility to the
P2
obstacle while motor 1 is working.
It set the sensibility to the
P5
obstacle while motor 2 is working.
Top set P2, P3, P5, P6 (cap.10)
EQ2009 R 1.6 1.8
It set the sensibility to the obstacle
P3
during slowing down of the 2 motors.
It set the speed of slowing down of the 2
P6
motors.
Working with 1 motor only, dip 5 OFF
without encoder
Rev. 02 del 2/05/2011
PHOTO 1
Motors
only