Belden Hirschmann GREYHOUND GPS1-C Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Interruptor Belden Hirschmann GREYHOUND GPS1-C. Belden Hirschmann GREYHOUND GPS1-C 20 páginas.

Belden Hirschmann GREYHOUND GPS1-C Manual do utilizador
Device variant Prerequisites:
Power supply
All of the following requirements are complied with:
module
characteristic
value K
Power supply
All of the following requirements are complied with:
module
characteristic
value P
Table 3:
Requirements for connecting the supply voltage
10
Supply with DC voltage:
Install a fuse suitable for DC voltage in the plus conductor of the power
supply.
Connect the minus conductor to the ground potential. If the minus
conductor is not connected to the ground potential, also install an external
fuse in the minus conductor.
Regarding the properties of this fuse:
See "Technical data" on page 72.
Supply with AC voltage:
Install a fuse in the outer conductor of the power supply.
Connect the neutral conductor to the ground potential. If the neutral
conductor is not connected to the ground potential, also install an external
fuse in the neutral conductor.
Regarding the properties of this fuse:
See "Technical data" on page 72.
The power supply complies with the requirements for a safety extra-low
voltage (SELV) according to IEC 60950-1 or ES1 according to IEC/
EN 62368-1.
The power supply is potential-free. For power supply modules capable of
PoE, exclusively use a potential-free SELV power supply.
Install a fuse suitable for DC voltage in the plus conductor of the power
supply.
Regarding the properties of this fuse:
See "Technical data" on page 72.
With redundant power supply: A positive grounding is prohibited.
Installation GREYHOUND Switch