Dantel A18-05775-00 Manual de instalação e operação - Página 3

Procurar online ou descarregar pdf Manual de instalação e operação para Controlador Dantel A18-05775-00. Dantel A18-05775-00 10 páginas. Order wire control and speaker monitor panel

CIRCUIT DESCRIPTION

F
ig. 1 shows the 05775 Order Wire and Speaker Monitor Panel
functional schematic.
The 05775 Panel monitoring section monitors all associated order
wire channels over the speaker. Incoming calls couple to the
speaker through transformers, operational amplifiers, and a
volume control potentiometer.
The push-button speaker monitor channel selector monitors any
one or two channels through an additional volume control potenti-
ometer. This option allows the selected channel(s) to be monitored
at a louder level. The unselected channels are still available for
monitoring at a quieter level.
A fuse and fuse alarm indicator LED are located on the front
panel. When the fuse blows, the alarm indicator LED lights up.
The control section is used to originate a call or answer an incom-
ing call on an individual order wire channel. Pressing the channel
button connects the handset to the respective order wire channel.
A headset may be used instead of the handset.