Safety and warning instructions,
Warning
location and ex-
haust fumes
Warning,
physical handling
Caution
Caution
6
Location
Never operate the heater in a confined space without adequate ventilation. The heater
should be located externally, and the heat transferred to the shelter by the insulated
flexible ducts. The location of the heater should avoid any possibility of ingesting ex-
haust fumes from other sources such as vehicles, generators or other engines. Any local
downdrafts of air with associated fumes should be avoided.
Fumes
Should at any time personnel in the heated shelter experience fuel odour or fumes the
heater is to be shut down and the source investigated. If the source of the fumes cannot
be detected and eliminated the heater must be changed and the defective heater in-
spected for combustion chamber cracks or other defects responsible for the fumes.
Obstruction of air intakes and ducts
Ensure that all air intakes/ducts, and where fitted, exit ducts are totally free from the
ingress of vermin or debris. Take corrective action to clean/remove obstructions on a
regular basis.
Lifting and movement
The weight of the heater is shown in the specifications, page 83 and is beyond the safe
handling of one person. Lifting and/or movement should be either undertaken by Me-
chanical Handling Equipment (MHE) or by sufficient numbers of personnel correctly lo-
cated around the heater so as to avoid injury or strain. When lifting the handrails are to
be used.
If the heater has been stored for an extended period the heater should be run for 5
minutes before connecting the air ducts.
Do not disconnect the power until the air supply fan has completely stopped.
continued