Aeware In.k200 Cartão de referência rápida - Página 3

Procurar online ou descarregar pdf Cartão de referência rápida para Controlador Aeware In.k200. Aeware In.k200 4 páginas. Compact full-function keypads for in.xe spa systems
Também para Aeware In.k200: Manual (12 páginas)

Aeware In.k200 Cartão de referência rápida
F 2
Programming purge cycles
To program the purge cycles, you must select the frequency. During a purge cycle, all pumps
and the blower run for one minute. To set purge cycles:
F 2
Setting filter cycle duration
Press and hold Light key until the display shows dxx, with
"xx" representing the duration in hours. (Default: 2 hours).
Use Up or Down key to change setting.
0 = no filtration
24 = continuous filtration
Note: it's not recommended to set this to "0".
Filter cycle frequency
Press Light key again. The display will show Fx, with "x"
representing the number of filter cycles per day (up to 4).
(Default: twice a day).
Use Up or Down key to change setting.
When the desired setting is displayed, press Light
key to confirm. A filter cycle will start immediately.
The "Filter" indicator lights up
when a filter cycle is on.
Setting the temperature display units
To set the temperature display units, quick press Light key
again. The display will show either°F or °C.
Use Up or Down key to change units.
Press Light key a last time to go back to normal mode.
°F = Fahrenheit
°C = Celsius
Purge cycle frequency
Press and hold Light key until the display shows Fx, with "x"
representing the number of purge cycles per day (up to 4).
Use Up or Down key to change setting.
When the desired setting is displayed, press Light
key to confirm. A purge cycle will start immediately.
The "Filter" indicator lights up
when a purge cycle is on.