8
WIRING RECOMMENDATIONS
With the ASA468 Adapter, several wire types can be used. There are only a few
simple rules to follow, mostly for safety and/or operational integrity reasons. The
following wire types have been tested and represent a large majority of wire types
that may be encountered in retrofit installations.
M&S MS4XSC – 22 ga., 2-pair solid conductors with individual shields and gray
outer insulation (essentially, 2 sets of high grade differential audio cable in one
sheath), used for M&S wall stations. This cable can be used as 3 pairs by taking
advantage of the 2 shield (drain) wires which are insulated from each other as long
as the inside ends of the individual foils or the wires themselves don't touch each
other.
When using as 2-pair cable only, simply use the individual pairs and leave the
shields unconnected. This will only allow for one media bus operation.
The shield wires can be used as a third pair thus allowing the second media bus
operation. Our recommendation is to use one of the pairs for power (pins 1&2)
and the second pair for media bus 2 (pins 5&6). The shield wires should then be
used for the data bus (pins 3&4) since it operates at a lower frequency and is less
susceptible to the impedance mismatch created by the shield wires. The individual
shield wires should be insulated with a sleeve to keep them from shorting together.
Another sleeve (e.g., heat shrink tubing) should be installed over the end of each
foil to prevent them from touching each other. It is highly recommended that the
shield wires not be used as the power conductors (pins 1&2) since, if they do short
together, the resulting damage would be far worse than if the data bus shorted out.
M&S MS4DCXSC – 22 ga. 2-pair solid conductors with individual shields and
orange outer insulation, used for M&S door stations. See MS4XSC, above.
Nutone IW-6 – 22 ga. 3-pair solid conductors. This cable is excellent in
retrofit installations since it works well with the ASA468 Adapter and no
special precautions are needed.
Wires That Don't Work
The following wire types have been tested and WILL NOT WORK:
Nutone IW-4
M&S MS4X - 22 ga. 4 conductor flat ribbon cable
M&S 7-conductor for discontinued model 902