You should provide sufficient air entrance for the combustion in the installation place. The diameter of the
opening for the connection must correspond at least to the diameter of the smokes pipe (Ø120 mm). The
opening must be equipped with a wall connection for the reception of the exhaust pipe.
Before installation, verify if your floor can support the weight of the stove, and in case that the bearing
capacity of the floor is insufficient perform measures for increasing the capacity.
The manufacturer is not responsible in case of modification of the product and for the use of not original
spare parts.
12. FIRE SAFETY
In the installation of the stove the following safety measures are to be followed:
a) In order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or
furnishing components flammable and sensitive to heat (furniture, wooden objects, fabrics etc.) and from
materials with flammable structure. All the minimum safety distances are shown on the product data plate
and lower values must NOT be used.
b) In front of the chimney stove there must not be any flammable object or building material, sensitive to
heat, at less than 100 cm distance. If the stove is installed on a foundation made of flammable materials,
the foundation must be covered with fireproof plates.
c) If the product is installed on a floor which is not completely fire resistant, one must foresee a fireproof
background, for example a steel platform dimensions according to the local regulations. The platform must
stick out 30 cm sideways and 50 cm on the front side over the loading door.
d) No flammable components must be present above the product.
The chimney stove must operate exclusively with the ash drawer inserted. The solid residue of the
combustion (ashes) must be collected in a hermetic container, resistant to fire. The stove must never be
ignited when there is gas or steam emissions (e.g. glue for linoleum, gasoline, etc.). Never deposit
flammable materials near the stove. During the combustion there will be a spread of thermal energy which
warms up the surfaces, the door, the fireplace glass, the handles and knobs, the smoke pipe and the front
side of the stove. Please avoid the contact of these parts without gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney
fire.
FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door;
b) Close the controls of combustion air;