Contrast Control
The Programmer's LCD contrast can
LOOP OFF
Address
be adjusted between a value of 30
Device Info
and 60; the default setting is 40.
Test Device
>
SETTINGS
Select SETTINGS > DISP
Shutdown
CONTRAST menu (shown right).
Press the UP / DOWN buttons to
set the contrast level, then press
the ACCEPT button to confirm.
Battery Voltage Status
This menu checks the
LOOP OFF
LOOP OFF
Address
Programmer's battery voltage.
Device Info
Test Device
Select SETTINGS > BATTERY VOLTS
>
>
SETTINGS
menu (shown right) and the
Shutdown
battery voltage is displayed.
About
This menu displays the Programmer's firmware version.
Select SETTINGS > ABOUT menu.
Technical Specification
Description / Part No.:
Communication Protocol:
Internal Battery Power:
Battery Life:
Loop Operating Voltage:
Quiescent Current (Operated):
Display:
128 × 64 LCD type (viewing area 50 mm diagonal) c/w backlight
Sockets:
Material:
Weight:
Overall Dimensions:
IP Rating (EN 60529):
Operating Temperature:
Humidity:
Note: The Programmer contains sensitive electronic equipment. It is designed for indoor use only
and MUST NOT be subjected to conditions likely to affect its performance.
E&OE. No responsibility can be accepted by the manufacturer or distributors of this unit for any misinterpretation of this instruction, or for the compliance
of the system as a whole. The manufacturers policy is one of continuous improvement and we reserve the right to make changes to product specifications
at our discretion and without prior notice.
4 of 4
Approved Document No. DFU4165000 Rev 3
LOOP OFF
LOOP OFF
Display Contrast
>
DISP CONTRAST
=============
Battery Volts
Contrast : 40
About
LOOP OFF
LOOP OFF
Battery Volts
Disp Contrast
==========
>
BATTERY VOLTS
Volts = xxxxmV
About
CAST Hand-Held Device Programmer / CAPROG
`CAST´ (C-TEC)
4 × 1.5 V AA battery (alkaline, non-rechargeable)
10 - 12 hours minimum (one battery set)
36 Vdc
30 mA
2 × jack sockets (4 mm)
ABS polycarbonate
325 g (without batteries)
225 mm (H) × 117 mm (W) × 65 mm (D)
IP20
-10
o
C to +70
o
C
Max. 95% RH (non-condensing)
CAST HAND-HELD DEVICE PROGRAMMER (CAPROG)
USER INSTRUCTIONS
Features
Programs device addresses and tests device operation.
Compact, robust design with user-friendly menus.
Battery powered with battery status indication.
Auto shutdown feature.
Integrated LCD c/w illuminated backlight and
adjustable contrast.
Integrated base for direct connection to CAST head
devices.
Integrated base jack sockets (black & red) for remote
connection to CAST ancillary devices.
Description
The CAST Hand-Held Device Programmer, Part No. CAPROG, is a portable tool that assists
commissioning / maintenance personnel with setting device addresses and testing device
operation.
The Programmer is compatible with the full CAST analogue detector range and other CAST
protocol devices, as listed below:
CAST Analogue Fire Detectors, CAST Manual Call Points, CAST Sounders/VADs, CAST Voice
Item Supplied with the Programmer
1 x Remote Connector Lead (shown right).
Device Connections
Note that the Programmer's power may be on or off when connecting / disconnecting devices.
Once connected, ensure that loop power is OFF, as indicated by `LOOP OFF´ displayed top-left
on the Programmer's LCD. Note that when the Programmer's main menu is displayed, loop
power is off.
Connecting CAST Head Devices: Twist-fit the device's head directly into the Programmer's base.
Ensure the device head `clicks´ securely into the base.
Connecting CAST Manual Call Points, I/O Units and CAST Ancillary Devices: Using the remote
connector lead (supplied), connect from the Programmer's two jack sockets (black & red) to the
device's connector block or screw terminals. Ensure correct polarity; red connector (positive) and
black connector (negative).
CAST Range
CAST Range
CONNECTOR FOR MCP, I/O UNIT
& ANCILLARY DEVICES
Approved Document No. DFU4165000 Rev 3
2 x 4 mm
Jack Sockets
(black & red)
CAST Device
Base
LCD
Membrane
Keypad
1 of 4