Mount the PIR detector in one of 2 m. At this height,
the detection range of the detector is optimised, i.e. 12
metres range and 90° detection angle.
The PIR detector ignores pets up to a height of approx.
60 cm in this installation.
Mount the PIR detector slightly higher if the detector is
still
triggered
by
the
pet.
Do not mount the detector too high, otherwise it will
not be triggered by humans.
Use the bracket as a template to mark the position of
two drill holes on the wall. There are two markings
each for wall or corner mounting.
Fix the bracket to the wall using the supplied plugs and
screws.
Do not overtighten the screws to avoid damaging the
bracket.
Place the base on the bracket and then press the unit
against the wall.
Connect the two parts again with the metric screw.