Duratool D03128 Manual - Página 7
Procurar online ou descarregar pdf Manual para Instrumentos de medição Duratool D03128. Duratool D03128 16 páginas. Clamp meter
Range
Resolution
400mV
0.1mV
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Range Resolution
4V
0.001V
40V
0.01V
400V
0.1V
750V
1V
Frequency by a range (from current clamp)
Range Resolution
10Hz
0.01Hz
1kHz
0.001kHz
>1kHz 0.001kHz
Frequency by ACV range
Range
Resolution
10Hz
0.01Hz
1kHz
0.001kHz
10kHz
0.01kHz
>10kHz 0.01kHz
Frequency by Hz/Duty Cycle range
Range
Resolution
9.999Hz
0.001Hz
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999KHz
0.001kHz
99.99KHz
0.01kHz
999.9KHz
0.1KHz
9.999MHz 0.001Mhz
DC Voltage
Accuracy
± (1.0% of rdg + 2 digits)
± (0.7% of rdg + 2 digits)
± (0.8% of rdg + 2 digits)
AC Voltage
Accuracy
± (0.8% of rdg + 3 digits)
± (1.0% of rdg + 4 digits)
Accuracy
± (1.5% of rdg + 5
digits)
Accuracy
± (1.5% of rdg + 5
digits)
Take it only as reference
Accuracy
± (0.5% of rdg + 3
digits)
• Input impedance: 10MΩ.
• Max. input voltage: 1000V DC.
• At small voltage range, unsteady
readings will appear before the test
leads contact the circuit. This is
normal because the meter is highly
sensitive. When the test leads
contact the circuit, the true reading
will be shown.
• Input impedance: 10MΩ.
• Max. input voltage: 750V rms AC.
• Frequency range: 40 to 400Hz.
• Response: Average value.
• Measurement range: 10 ~ 1kHz.
• Input current range: ≥ 4A rms AC
(higher input current at higher
frequency).
• Max. input current: 400A rms AC.
• Measurement range: 10 ~ 10kHz.
• Input voltage range: ≥ 0.6V rms
AC (higher input voltage at higher
frequency).
• Input impedance: 10MΩ.
• Max. input voltage: 750V rms AC.
• Overload protection: 250V DC or
250V AC rms.
• Input voltage range: 200mV-10V
AC rms.
7