DuraVent DIS1 14 L36 BC Manual de instruções - Página 5

Procurar online ou descarregar pdf Manual de instruções para Campânula de ventilação DuraVent DIS1 14 L36 BC. DuraVent DIS1 14 L36 BC 16 páginas. Positive pressure systems

Maximum Vertical Spacing between ANY Guide / Supports and
TABLE 4
Maximum Freestanding above the Roof
DCL
DAS1 / DIS1
MODEL
HEIGHT (ft)
HEIGHT (ft)
Flue
Diameter
MVS*
H*
MVS*
Ø (in)
5
20
8' 6"
20
6
20
9' 6"
20
7
20
10'
20
8
20
10' 9"
20
9
20
11' 6"
20
10
20
12'
20
11
20
12' 6"
20
12
20
13'
20
13
20
13' 6"
20
14
20
14'
20
16
20
14' 6"
20
18
20
15'
20
20
20
15'
20
22
20
15'
20
24
20
15'
20
26
20
15'
20
28
20
15'
20
30
20
15'
20
32
20
15'
20
34
20
15'
20
36
20
15'
20
Maximum Vertical Spacing between two (2) Guides or
MVS*
Support
and Guide in a Vertical Position
Maximum Freestanding Height above the roof.
H**
This limited height is due to wind loads.
Dimensions are in inches (diameter) and feet (distance)
 
 
 
TABLE 5 – maximum Horizontal Spacing between each Guide / Support
Flue 
Product 
Diameter 
Ø (in) 
 
Half Angle Ring 
5 to 12 
(HAR) / 
Full Angle Ring 
(FAR) / 
Anchor Support 
14 to 24 
(AP) / 
Anchor Plate with 
Length (APL) / 
Heavy Duty Wall 
26 to 36 
Guide (HDWG) 
 
Dimensions are in inches (diameter) and feet (distance)
 
 
 
 
 
DIS2
DIS4
HEIGHT (ft)
HEIGHT (ft)
H*
MVS*
H*
MVS*
7' 3"
20
6' 6"
20
8' 3"
20
7' 6"
20
8' 9"
20
8' 3"
20
9'
20
8' 6"
20
9' 3"
20
8' 9"
20
9' 6"
20
9'
20
9'9"
20
9' 3"
20
10'
20
9' 6"
20
10' 3"
20
9' 9"
20
10' 6"
20
10'
20
11'
20
10' 6"
20
11' 6"
20
11'
20
12'
20
11' 6"
20
12' 3"
20
11' 9"
20
12' 9"
20
12' 3"
20
13'
20
12' 6"
20
13' 6"
20
13'
20
13' 9"
20
13' 6"
20
14' 3"
20
13' 9"
20
14' 6"
20
14' 3"
20
15'
20
14' 6"
20
Distance (ft)
DCL 
DAS1 
DIS1 
DIS2 
DIS4 
23 
23 
19 
16 
19 
19 
16 
14 
15 
15 
13 
11 
S
R
UBMITTAL 
ECORD FOR 
M&G
D
 
URA
H*
5' 9"
6' 9"
7'
7' 3"
7' 6"
7' 9"
8'
8' 3"
8' 6"
9'
9' 6"
10'
10' 9"
11'
11' 6"
12'
12' 3"
12' 9"
13' 3"
13' 6"
13' 9"
EXTERIOR CORROSION PROTECTION
It is recommended to apply an exterior grade high heat paint to any
plate supports, full/half angle rings, wall guides, aluminized outer
walls for corrosion protection against the elements.
EX: Rust-Oleum V200 series High Heat Industrial Aerosol

SEISMIC REQUIREMENTS

In certain areas of the country, local codes contain requirements to
address seismic risks.
grease ducts usually include specifications for additional "sway bars" /
bracing, or similar devices in order to help stabilize the system in the
event of an earthquake.
Specific guidelines (including spacing, location, size and method of
attachment of bracing / sway bars or other devices for addressing
seismic requirements vary depending upon the adopted code,
12 
seismic zone, duct size, location in building, etc. and are not within
the scope of this document.
Consult with a design professional in order to determine compliance
10 
options for these potentially complex requirements when this product
is to be installed in a building where these additional requirements
apply.
The support methods described in this document have been proven
adequate (via UL certification) for locations where there are no
additional seismic zone requirements. In order to address additional
seismic requirements they may be further supplemented with a
variety of generic sway bars or braces that attach to or around the
outer wall of the chimney / grease duct system. Full Angle Rings
(FAR) and Half Angle Rings (HAR) may be included as components
of such supplemental bracing.
 
 
D
S
M
DCL,
DAS1,
URA
TACK 
ODELS 
 
V
|
10
J
L
|
A
ENT 
 
 
UPITER 
ANE 
 
LBANY
www.duravent.com 
Seismic requirements for chimneys and
DIS1,
DIS2
DIS4 
 
 
 AND 
,
N
Y
 
 
EW 
ORK