Lintel hook should be mounted in a position
so as to provide a small amount of tension in
the spring attached to the chain (Fig. 3). The
tension is needed to prevent the damper plate
from rattling when closed. mount the Lintel
hook to the masonry with the screws provided.
4. Attach Chimney: Attach the first Chimney
Section onto the Anchor plate by using the
sheet metal screws provided. Always maintain
at least a 2-inch clearance to combustibles.
The 2-inch clearance is an air space; do not
fill that clearance space with any materials. If
an offset is required, refer to the elbow Offset
Installation Section below.
5. Frame Openings: From the ceiling, drop a
plumb bob to the center of the fireplace's flue
outlet and mark this center point on the ceiling.
refer to Table 1 for the framing dimensions.
mark appropriate cutting lines around the
center point. Cut a square hole in the ceiling.
Frame a level, square opening centered over
the hole that you have cut. Frame openings at
each floor level above the Fireplace (Fig. 4).
These openings are to hold the Firestop and
Attic Insulation Shield. Locate each opening by
dropping a plumb bob to the four corners of the
opening below. maintain the minimum 2-inch
clearance/air-space.
6. Cut Roof Opening: If penetrating through
the roof, determine and cut an opening in the
roof directly above the opening below. The
cut opening must be at least 4-inches larger
than the chimney's outside diameter to provide
at least a 2-inch clearance all around the
chimney. The chimney must be centered within
this opening and maintain the minimum 2-inch
clearance to combustibles.
7. Install Firestop: A Firestop is required on
each floor penetration in multistory installations.
Building Codes require a Firestop at every
floor/ceiling level, including where the chimney
NorthlineExpress.com
http://www.northlineexpress.com
TERMINATION
CAP
STORM
COLLAR
CHIMNEY SECTION
Figure 4
Toll-Free 1-866-667-8454
CHASE TOP
FLASHING
(4) ROOF
RADIATION
SHIELDS
ATTIC INSULATION
SHIELD & COLLAR
SQUARE FRAME
FIRESTOP
CHIMNEY
SQUARE FRAME
FIRESTOP
ANCHOR PLATE
OR ANCHOR PLATE
WITH DAMPER
FIREPLACE
7