Step 5: Install the Switch Plate with mounted Rotary
switch on Electric Box
• Note: Only mount the Switch Plate on the Electric box when all
electrical connection in box have been completed
• Attach the Switch Plate to the electric box using the screws
supplied with the switch plate (taped to the back). Make sure
the locking tab is facing up
Step 6: Install the Rotary Switch Knob
• Using a 1/16" allen wrench, loosen the set screw on the side
of the knob slightly
• Place the knob onto the rotary switch shaft. The black
indicator line should face straight up
• Tighten the set screw using the 1/16" allen wrench
Step 7: Power Up
• Power up the Lunos e2 system and verify fans are running and
responding to Rotary switch settings
ROTARY SWITCH OPERATION
• Knob position: 12 o'clock = Off
• Knob position: 1 o'clock = Low
• Knob position: 2 o'clock = Med
• Knob position: 3 o'clock = High
• Rotating from Low to Med and back to Low again (within 3
seconds) will put the system into summer vent mode
(ventilation without heat recovery). Repeat those actions to
transition out of summer vent mode, back to heat recovery
mode.