Aplisens MS-100 Manual do utilizador - Página 6

Procurar online ou descarregar pdf Manual do utilizador para Instrumentos de medição Aplisens MS-100. Aplisens MS-100 8 páginas. Industrial pressure gauges (manometers); pressure gauges with diaphragm seals

IO.MS-100.01(EN)

7. MAINTENANCE

Manometers are maintenance free devices and work within the ranges specified by the manufacturer.
It is recommended to inspect the manometer every 6 months in order to check the indication accuracy
thus determining whether a given manometer still complies with the accuracy class.

8. IDENTIFICATION AND MARKING FOR ORDERING

8.1
. Each manometer and manometers with separators are equipped with a data plate with at least
the following data: name of manufacturer, type of manometer, type of diaphragm seal and measuring
range.
8.2
. Ordering procedure for MS-100K manometers.
Measurement range
Special version: glycerine, T
Example: Manometer MS-100K / range 0 ÷ 6 bar / glycerine / G1/2" connection
. standard)
8.3
. Ordering procedure for MS-100 manometers
Measurement range
Special version: glycerine, T
Example: Manometer MS-100 / range 0 ÷ 6 bar / glycerine, standard radial connector / tantalum
chemo-resistant diaphragm seal DN50

9. PACKING, STORAGE AND TRANSPORT

Manometers should be packed in unit and/or bulk packaging in such a way to protect them from
damage in transportation. They should be stored in bulk packaging in covered rooms, free from
vapour and aggressive substances in temperature and humidity not exceed the limits specified in p. 4.
In the case of manometers with diaphragm seals stored without packaging, the membranes should
have covers protecting them from being damaged.
The manometers should be transported in protected packaging. The means of transportation may be
road, sea or air, provided it eliminates direct atmospheric impact. Transportation conditions according
to PN-81/M-42009.
4
MS-100K / __÷ __ / ___/ ___/ ___
MS-100K / 0 ÷ 6 bar / glycerine / G1/2"
MS-100 / __ ÷ __ / ___ / ___ / ___
MS-100 / 0 ÷ 6 bar / glycerine / S-Ch tantalum - DN50
MC3.1-Material certificate
NACE-NACE MR-01-75comply
Type of process connection
(G1/2", M20x1,5)
MC3.1-Material certificate
NACE-NACE MR-01-75comply
Type of diaphragm seal
C