Abus Vitess Rim Manual de serviço - Página 11
Procurar online ou descarregar pdf Manual de serviço para Fechaduras Abus Vitess Rim. Abus Vitess Rim 20 páginas.
CALCULATION RULES
Recommended according to German standards.
•
When using one key-way for KD/KA and MKS calculate with 2-step-progression (code groups, even, odd)
•
Maximum repeated depths/cuts per key: 3
525226
525525
•
Maximum consecutive repeated depths/cuts per key: 2
535226
533342
•
No stair-step depths/cuts
543210
•
At least 1 minimum jump of 4 steps
546243
543454
Calculation Rules Specific to Vitess™
•
First chamber is fixed: Intop pin no. 5
•
No master pins on chamber 1
•
2nd pin can only "jump" 4 heights upwards or downwards.
513624
503624
•
Remaining chambers max jump is 6
517174
518184
•
Due to the profile check pin we recommend not to use master pins no. 2 (only 4 or larger), however 2 can be used
in case of "emergency" (no more codes available)
MASTER KEY SYSTEM MANAGEMENT
2-Step Progression (Even/Odd)
•
2-step progression allows us to manage all codes/pins/cuts that our system can use
to generate codes for our master key systems or simply KD/KA cylinders; this way no
keys would be repeated
•
Odd/even codes management: B = odd
•
6 pins generate 64 groups (Even/Odd) from AAAAAA to BBBBBB
•
Depending on the size/complexity one group might be used for more then just one
master key system
A = even
Even A
Odd B
Z
Y
X
0
1
2
3
4
5
6
7
8
9
11