4Ddoors DX250 SA Instruções de montagem, operação e manutenção - Página 8
Procurar online ou descarregar pdf Instruções de montagem, operação e manutenção para Abertura de portões 4Ddoors DX250 SA. 4Ddoors DX250 SA 14 páginas. Hinge gate operator
ENGLISH
5.1.4 Mount operator motor
• Insert motor to plate, fi x with screws/nuts.
5
05 mount motor
5.1.5 Mount articulated arm
• Mount articulated arm, fi x arm on motor.
6
A
F
E
D
Note
Grease articulations before mounting. Switch on operator
not earlier than after complete mounting on gate
5.1.6 Adjust interruptor of end travel
● Disengage gate from operator (page 5), move gate into desired OPEN
/ CLOSE position (adjusting-ring must activate related end-of-travel
switch)
● Fix lower adjusting-ring with middle screw, upper adjusting-ring with
both side-screws.
5.1.7 Adjust end of travel: GATE CLOSED
● move gate into desired gate-CLOSED position.
● turn lower buckle (by key) until related end-switch is activated.
● fi x screw in the middle.
G
H
C
B1
G
B2
H
8
5.1.8 Adjust end of travel: GATE OPENED
● move gate into desired gate-OPENED position.
● turn upper buckle (by key) until related end-switch is activated.
● fi x both screws on the outside.
7
07 adjustment end travel interruptor
A = end travel OPEN interruptor
C = buckle OPEN
8
door closed
08 adjustment of buckles
Mechanical limit stops for end-positions gate CLOSE
and OPEN should be mounted!
Adjust both buckles to switch off at a position, the gate
contacts the mechanical limit stops. This way, the gate
will not „whip" back!
Check adjustment after the gate is completely installed.
Open and close the gate several times. For smooth
operation, a „fi ne-adjustment" is suggested.
A
B
C
D
B = end travel CLOSE interruptor
D = buckle CLOSE
key to
set buckles
lower buckle
upper buckle
Caution!
door open