AddSecure Edge RT7020 Enterprise Manual do utilizador - Página 11

Procurar online ou descarregar pdf Manual do utilizador para Sistema de segurança AddSecure Edge RT7020 Enterprise. AddSecure Edge RT7020 Enterprise 11 páginas.

AddSecure Edge RT7020 Enterprise Manual do utilizador
8.4

Power supply, consumption and working temperature

8.4.1

Power supply

Max 11-30 VDC, fused with external fuse 1A. When mounting the Edge
RT7020 in its own standard enclosure the power supply must be limited to
max 4A. This is required for both PWR and BAT separately.
8.4.2

Power consumption

In normal operation approximately 200 mA @ 12 VDC
8.4.3

Working temperature

-5 to +40 degrees Celsius
8.5

Approvals

Alarm transmission Intrusion
Alarm transmission Fire
The Edge RT7020 is designed for and manufactured according to the
ISO9001 quality system. All components used on the product have been
specifically selected to meet high demands on quality and functionality and
to operate within each component's specification given an ambient climate
in accordance with class3k5 in EN60721-3-3:1995.
EN50131-10, EN50136-1, EN50136-2
Class: SP6*/DP4
SSF114, larmklass 3-4
* SP6 via Ethernet, SP5 via cellular network
SBF110:8
CPR (EN54-21), "Alarm transmission and fault warning routing equipment
for fire alarm systems installed in buildings"
11