Durite 0-441-10 Manual de início rápido - Página 3
Procurar online ou descarregar pdf Manual de início rápido para Equipamento de iluminação Durite 0-441-10. Durite 0-441-10 4 páginas. Led high intensity warning light x 2 on mounting plate
1. Switch Patterns:
To change to next flash pattern:
With the LED Light Heads switched on, momentarily apply + VDC to YELLOW wires for less
than 1 sec-ond and release
To reset:
With the LED Light Heads switched on, quickly apply three times + VDC to YELLOW wires
and release. LED Light Head will reset to the factory default pattern (Pattern # 0, Random)
2. Synchronization: (More than 2 sets of LED Light Heads - 8 Light Heads Maximum!)
First, connect YELLOW wires of all heads together, quickly apply three times + VDC to YEL-
LOW wires and release for Pattern # 0, Random.
Secondly, momentarily apply + VDC to YELLOW wires to for less than 1 second and release
for Pattern # 1, then the synchronization will be functioned.
3. Alternating or Simultaneous Flash: (More than 2 sets of LED Light Heads)
Under Synchronization, connect WHITE wire of LED Light Head 1 to Red wires of all other
LED Light Heads; LED Light Head 1 will alternate with other LED Light Heads.
If the WHITE wire not connected to Red wires, all LED Light Heads will flash together (Si-
multaneous flash)
4. Flash Patterns: 20 selectable strobe patterns
WIRING DIAGRAM
FLASH PATTERNS
(Yellow wires touch Red wires)
www.durite.co.uk
0-441-10-LEAF