7.4 Connecting power
7.5 Fitting backup batteries for VS5051
7.6 Connecting voice panels and alarm transmitters
7.7 Connecting the terminal
7.7.1 Power Outputs
PDK-13010-v.6.0 Edge VS5010 and VS5051 User manual
3
Connect cables from the alarm panels, voice panels and alarm
transmitters to the terminal PCBA to the appropriate connections,
see section 7.5 "Connecting voice panels and alarm transmitters".
4
Finish this procedure by contacting the ARC to verify and test
alarm transmissions.
Power to the terminal must be provided from a power supply providing
10.5 to 28V DC with a recommended 1.6A current. The power supply must
be able to be connected using the screw terminals.
For the VS5051 only: If you have enabled the emergency light function, the
power supply must be connected to the same fuse as the elevator car light.
This also applies when the terminal is powered by the elevator controller.
IMPORTANT: You can connect the power supply but DO NOT APPLY
POWER TO THE TERMINAL NOW. Power will be applied later.
Connect the internal battery to the PCBA battery connector (22), see
section 6, "Board Configuration".
Note: Only use battery packs provided by AddSecure.
All voice panels or alarm panels sited in elevators use the two-wire Dial
Capture port (21), see section 6, "Board Configuration". For the best voice
quality make sure the voice panel is configured with full duplex
Note: The two-wire connection has no polarity so it can be connected
either way round.
Connect the voice panels or the alarm panels to the Dial Capture port (25),
see section 6, "Board Configuration".
Connect cables to the terminal PCBA to the appropriate connections, see
section 6, "Board Configuration".
The terminal supports a battery backed, 12V DC output, rated 500mA
continuous operation. This supply is shared via the following, independently
switchable outputs, see section 6, "Board Configuration":
⑨ Vout1, Emergency light If power to the Edge terminal is lost, the emergency
⑩ Vout2, Buzzer
power will turn on.
If the alarm button connected to the voice panel is
pressed and held for minimum 5 seconds, the terminal
will start calling the ARC, and then the buzzer will start
buzzing for 10 seconds. This time can be adjusted by
Addsecure technical support.
page 7