Testing the functionality

4
Order
1. Assemble the throat plate slide interrogator ( p. 5).
2. Connect the throat plate slide interrogator ( p. 10).
3. Test functionality.
To test the functionality of the throat plate slide interrogator:
1. Connect the machine to the power supply.
2. Set the main switch (2) on the control to position 1.
 The machine is ready for operation.
Fig. 16: Testing the functionality
(1) - Throat plate slide
3. Open the throat plate slide (1).
 The machine is now locked and not sewing.
Additional Instructions 867 M-TYPE - 00.0 - 05/2018
Testing the functionality
The display of the corresponding control panel shows the following
message:
• CLASSIC machines: 3109 (operation lock)
• PREMIUM machines: Service Stop 9922
You have successfully set up the throat plate slide interrogator.