Addvent AVIMI200 Manual do utilizador - Página 7
Procurar online ou descarregar pdf Manual do utilizador para Ventilador Addvent AVIMI200. Addvent AVIMI200 12 páginas.
aViMi
DISCONNECT THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT.
ELECTRICIAN WITH A WORK PERMIT FOR THE ELECTRIC UNITS UP TO 1000 V AFTER
CAREFUL READING OF THE PRESENT USER'S MANUAL. THE RATED ELECTRICAL
ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID
The fan is designed for 230 V/50 (60) Hz single-phase alternating current mains.
The fan shall be connected to power supply by means of insulated, durable and thermal-resistant cords (cables, wires) through the
external circuit breaker with a thermal-magnetic trip built into the stationary wiring to disconnect all the power mains phases.
The rated current must be not below the rated current consumption (refer to the «Technical data» section).
The QF external switch location must ensure free access for quick shutdown of the fan.
The recommended circuit breaker nominal current is 1 A.
The recommended wire cross section is 0.75 mm
The actual conductor cross-section selection must be based on its type, the maximum permissible heating, insulation, length and
installation method (in the air, pipes or inside walls).
Connect the cables to the terminal block incorporated inside the terminal box located on the fan casing in compliance with the fan
wiring diagram and the terminal designation.
The terminal designations are shown on the sticker inside the fan casing.
Fan wiring diagram:
50 (60) Hz
CONNECTION OF THE UNIT TO POWER MAINS IS ALLOWED BY A QUALIFIED
PARAMETERS OF THE UNIT ARE GIVEN ON THE MANUFACTURER'S LABEL.
ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED
AND WILL VOID THE WARRANTY.
.
2
~230 V
CONNECTION TO POWER MAINS
THE WARRANTY.
QF
7