(1) TEST MODE
Turn the LUX control and the TIME control
counter clockwise to the edge – the TEST
position.
Turn on the wall switch. The light starts warm-up
for 1 minute. During 1 minute warm-up period, the
light will stay on.
Walk through the detection area. The light turns
on when you move and turns off when you stop.
For a smaller coverage area, point the sensor
down; for a larger coverage area, point the sensor
up.
(2) TIME ADJUSTMENT
The TIME adjustment controls how long the light will
stay on after the motion has been detected.
About 5 seconds
(3) LUX ADJUSTMENT
The LUX adjustment determines at what light level the
lighting system will start operating when you set the
sensor to automatic operation.
(4) AUTOMATIC OPERATION
Turn on the wall switch. When the sensor detects
motion, the light automatically turns on. The built-in
photocell turns the sensor off and on according to the
light level selected by the LUX adjustment.
About 12 minutes
(5) MANUAL OVERRIDE CLICK TWICE
Automatic switching can be overridden to allow the
lighting to illuminate regardless of movement or light
sensitivity. Turn the switch OFF - ON - OFF - ON
within 2 seconds.
In manual override mode, the lighting will remain on
for approx. 4 to 6 hours regardless of movement. Then
the motion switch will return to automatic mode.
You can also manually set the motion switch to
automatic mode by turning it off for 10 seconds, and
then on again.
TROUBLESHOOTING
Light does not turn on:
Confirm that you have made a correct "wiring
connection".
Check if you have already turned on the
connected wall switch, or circuit breaker.
Examine if the bulb of the lighting system is in
good condition or loose.
Adjust the LUX control knob by turning it counter
clockwise.
Light remains on:
Make sure the wiring connection is correct.
SPECIFICATIONS
Power Requirement
Lighting Load
Detection Field
(at 20°C)
Swiveling Angle
Mounting Height
Sensor Operation
Time Adjustment
Lux Adjustment
Warm Up Time
Protection Class
Protection Degree
Safety
2
AC 220 ~ 240V / 50Hz
Up to 1000W Halogen/
Incandescent
Up to 400W Fluorescent
Up to 150W LED
Up to 200° and 12 meter
Vertical 35° Horizontal 70°
1.8 ~ 2.0m Wall Mount
or 2.5 ~ 4.0m Ceiling Mount
Auto/Manual Override
Approx. 5 sec ~ 12 min
Approx. 30 ~ 200 Lux
About 1 min.
II
IP44
CE