Installing the indoor unit

Positioning the mounting plate
Install directly on the wall
G Select a structural part of the wall, so that indoor unit can be installed
securely.
G Make sure the mounting plate is level before securing it.
The wall must be capable of carrying the weight of the indoor unit.
Note: The indoor unit must be installed more than 2.3m above the floor for the best
efficiency.
Install the piping hole
G Drill hole with 65mm core drill.
G Insert the through wall pipe into the hole
Note: Drill the hole from indoors to outdoors with a 5° downward inclination.
Indoor unit installation preparation
Install the drain hose
G Run the drain hose sloping downward.
Do not install the drain hose as illustrated (see figure 7).
G When connecting extension drain hose insulate the connecting part of
extension drain hose with a shield material.
Indoor unit electrical wiring
G The indoor unit electrical wiring is already connected to the indoor unit
during manufacture.
G If the wiring or any other part is damaged, please contact Addvent on
0117 923 5375.
Wrap the pipe and wiring.
G Hold down the end of the pipe, pull it out, form the extension part.
G Wrap the piping and wiring and pull them through the cut-off-tailings hole.
G When routing the pipe and wire from the left or right side of the indoor
unit, cut off the tails from the pipe holder if necessary.
NOTE: EMC Directive 89/336/EEC to prevent flicker impressions during the start of
the compressor (technical process) and the adverse influence caused by the
second harmonics of the compressor, the following installation conditions apply.
The power connection for the air conditioner has to be done at the main power
distribution. The distribution has to be of a low impedance, normally the required
impedance reaches at a 32A fusing point.
2
No other equipment has to be connected with this power line.
3
For detailed installation acceptance, please refer to your contractor with the power
supplier if restrictions do apply for products like washing machines, air conditioner
or electrical ovens.
4
For power details of the air conditioner, refer to the rating plate of the product.
5
For any further questions contact Addvent on 0117 923 5375.