iNode Care Sensor PHT – instruction manual
At the top of the window there is displayed following information:
the name of the iNode family – in this case iNode Care Sensor PHT;
the unique device identifier;
battery level: 100% means 3V or greater, while 0% it is 1,8V;
humidity;
pressure;
signal strength received by this device from the BT4.0 adapter or iNode LAN;
temperature;
At the Bluetooth tab there are following items:
Name: you can change default device name typing a new one in this text box. Its length is 16
characters maximum.
Tx power: determine the power the device broadcasts and simultaneously the range the device
can be scanned. If iNode Care Relay has set the scan range ~200m, and iNode Care Sensor
PHT has set the broadcast power -2dBm range 33% then effective distance from which the
device can be scanned is equal 200m*0,33=66m.
Eco advert mode: the battery saving mode. The device sends a broadcast frame in a 5-minute
interval. To use this mode, you must properly configure the iNode Care Relay (switch-on time
may not be less than 10 minutes). Besides, if you want the iNodeSetup.exe application can
connect with your device you must first move it, and then turn on the scan.
Send alerts: allows you to enter to which logical groups will be sent alerts.
Advertising: you can chose the channels the iNode Care Sensor PHT broadcasts advertising
frames. This way the battery life can be extended but device can be more difficult to scan.
Additionally the advertisement interval can be chosen. This time determine how fast you can
connect with the device.
You can save modified settings by pressing the Write button.