Detector position and installation
 Install the detector in a weatherproof housing.
 The detector should be as close to the sensing loop as possible.
 The detector should always be installed away from strong magnetic fields.
 Avoid running high voltage wires near the loop detectors.
 Do not install the detector on vibrating objects.
 When the control box is installed within 10 metres of the loop, normal wires can be used to connect the
control box to the loop. More than 10 metres requires the use of a 2 core shielded cable. Do not exceed
30 metres distance between control box and loop.

Troubleshooting

Symptoms
If the detector is not working
If red led indicator is not fully lit
If green led
indicator:
If no: of turns is not enough
If no: of turns is too many
Manufactured by
Elsema Pty Ltd
,
31 Tarlington Place
Smithfield
NSW 2164, Australia
Ph: 02 9609 4668
Fax: 02 9725 2663
Website: http://www.elsema.com
Press reset
Check for power supply
It maybe because the loop is short circuit or the no: of turns is not
Blinks slowly
enough.
Blinks faster
It maybe because the loop is open or the no: of turns is too many.
Lower the frequency (if the frequency is still too high, you must add
more turns).
Higher the frequency (if the frequency is still too low, you must
remove some turns).