Datalogic DX6400 Manual de referência rápida - Página 7

Procurar online ou descarregar pdf Manual de referência rápida para Leitor de código de barras Datalogic DX6400. Datalogic DX6400 17 páginas.

Datalogic DX6400 Manual de referência rápida
The DX6400 scanner provides a 25-pin (26-pin for Ethernet models) male D-sub connector for connection to
power supply, Host interface (Main and Aux), and input/output signals.
Pin
Name
1
CHASSIS
20
RXAUX
21
TXAUX
8
OUT 1+
22
OUT 1-
11
OUT 2+
12
OUT 2-
16
OUT 3A
17
OUT 3B
18
EXT_TRIG/PS A External trigger (polarity insensitive) for PS
19
EXT_TRIG/PS B External trigger (polarity insensitive) for PS
6
IN2/ENC A
10
IN2/ENC B
14
IN3A
15
IN4A
24
IN_REF
9, 13
VS
23, 25, 26 GND
Pin
RS232
2
3
4
5
7
GND_ISO
* Do not leave floating, see Reference Manual for connection details.
Two 9-pin connector(s) provide access to the scanner's local Lonworks network.
The Standard Master/Slave model has two Lonworks connectors used for both input and output connections to
build a multi-sided or omni-station system.
The Fieldbus model (Ethernet) has one Lonworks connector and therefore can be used in a Lonworks network
only as a Master. For this model the Lonworks bus is internally terminated (no BT-6000).
Pin
Name
1
CHASSIS
9
VS
2
GND
6
VS_I/O
3
Ref_I/O
4
SYS_ENC_I/O
5
SYS_I/O
7
LON A
8
LON B
25-pin / 26-pin D-Sub Connector Pinout
Function
Chassis - internally connected to GND
Cable shield connected to chassis
Receive data of auxiliary RS232 (referred to GND)
Transmit data of auxiliary RS232 (referred to GND)
Configurable digital output 1 – positive pin
Configurable digital output 1 – negative pin
Configurable digital output 2 – positive pin
Configurable digital output 2 – negative pin
Configurable digital output 3 – polarity insensitive
Configurable digital output 3 – polarity insensitive
Input signal 2 (polarity insensitive) for Encoder
Input signal 2 (polarity insensitive) for Encoder
Input signal 3 (polarity insensitive)
Input signal 4 (polarity insensitive)
Common reference of IN3 and IN4 (polarity insensitive)
Supply voltage – positive pin
Supply voltage – negative pin
Main Interface
TX
RX
RTS
CTS
9-pin Lonworks Connector Pinout
Function
Cable shield internally connected
by capacitor to chassis
Supply voltage – positive pin
Supply voltage – negative pin
Supply voltage of I/O circuit
Reference voltage of I/O circuit
System signal
System signal
Lonworks line (polarity insensitive)
Lonworks line (polarity insensitive)
RS485 Full-Duplex
TX485+
* RX485+
TX485-
* RX485-
GND_ISO
5
9
9-pin Local Lonworks Connectors
DX6400 QUICK GUIDE
1
14
25-pin male D-sub Connector
1
10
19
26-pin male D-sub Connector
RS485 Half-Duplex
RTX485+
RTX485-
GND_ISO
1
1
6
6
Female
Male
(Standard model only)
13
25
9
18
26
5
9
7